Verified boiler fault code
Ferroli F05 Fault Code (i25 / i29)
Air-pressure switch did not close within 20 seconds of fan activation.
Safety disclaimer
Fault code summary
- Manufacturer
- Ferroli
- Fault code
- F05
- Fault type
- Fan, Flue, Electrical
- Severity
- temporary
- Reset
- Ferroli states that F faults reset automatically when the value returns to the normal range.
- Applicable models
- Ferroli i25, Ferroli i29
Quick answer
Air-pressure switch did not close within 20 seconds of fan activation.
What does this fault code mean?
Air-pressure switch did not close within 20 seconds of fan activation.
Common causes
- Air-pressure switch contact open.
- Pressure-switch wiring fault.
- Wrong baffle.
- Obstructed or incorrectly sized flue.
- Dirty exchanger.
- Faulty water circulation.
Symptoms
- The display flashes F05 and the boiler temporarily shuts down.
What can the homeowner safely check?
- Do not obstruct, dismantle or alter the flue; contact a qualified engineer.
Boiler reset information
Ferroli states that F faults reset automatically when the value returns to the normal range.
When should I call an engineer?
Contact a suitably qualified heating engineer when the fault persists, the boiler locks out, or the manufacturer instructions do not resolve it. For gas appliance work in the UK, use a Gas Safe registered engineer.
Engineer diagnosis
- Check air-pressure switch, fan, wiring, baffle, flue and circulation.
Applicable boiler models
Related fault codes
- A01 — i25 / i29
No burner ignition.
Read fault code - A02 — i25 / i29
Flame-present signal with the burner off.
Read fault code - A03 — i25 / i29
Overtemperature protection intervention.
Read fault code - A06 — i25 / i29
No flame after the ignition phase.
Read fault code - A09 — i25 / i29
Gas-valve fault.
Read fault code - A15 — i25 / i29
Air-pressure-switch fault F05 generated five times in the last 24 hours.
Read fault code - A16 — i25 / i29
Gas-valve fault.
Read fault code - A23 — i25 / i29
Card parameter fault.
Read fault code
Manufacturer documentation
i25 / i29 Instructions for use, installation and maintenanceTable 9: F05 — Air pressure switch fails to close contacts within 20 sec. of fan activation; table lists switch, wiring, baffle, flue, exchanger and circulation causes.
Last verified
2026-09-12
Frequently asked questions
What does Ferroli F05 mean?
Air-pressure switch did not close within 20 seconds of fan activation.
Can I reset a Ferroli F05 fault?
Ferroli states that F faults reset automatically when the value returns to the normal range.