Verified boiler fault code
Ferroli A01 Fault Code (i25 / i29)
No burner ignition.
Safety disclaimer
Fault code summary
- Manufacturer
- Ferroli
- Fault code
- A01
- Fault type
- Ignition, Gas supply
- Severity
- lockout
- Reset
- Ferroli states that A faults cause permanent shutdown and may be restored with the RESET button only after the fault is eliminated.
- Applicable models
- Ferroli i25, Ferroli i29
Quick answer
No burner ignition.
What does this fault code mean?
No burner ignition.
Common causes
- No gas.
- Ignition/detection electrode fault.
- Faulty gas valve.
- Ignition power too low.
- Excessive condensate level.
Symptoms
- The display flashes A01 and the boiler permanently shuts down.
What can the homeowner safely check?
- Check only whether other gas appliances are also affected; do not work on gas components.
Boiler reset information
Ferroli states that A faults cause permanent shutdown and may be restored with the RESET button only after the fault is eliminated.
When should I call an engineer?
Contact a suitably qualified heating engineer when the fault persists, the boiler locks out, or the manufacturer instructions do not resolve it. For gas appliance work in the UK, use a Gas Safe registered engineer.
Engineer diagnosis
- Investigate gas supply, ignition/detection electrode, gas valve and condensate trap.
Applicable boiler models
Related fault codes
- A02 — i25 / i29
Flame-present signal with the burner off.
Read fault code - A03 — i25 / i29
Overtemperature protection intervention.
Read fault code - A06 — i25 / i29
No flame after the ignition phase.
Read fault code - A09 — i25 / i29
Gas-valve fault.
Read fault code - A15 — i25 / i29
Air-pressure-switch fault F05 generated five times in the last 24 hours.
Read fault code - A16 — i25 / i29
Gas-valve fault.
Read fault code - A23 — i25 / i29
Card parameter fault.
Read fault code - A24 — i25 / i29
Card parameter fault.
Read fault code
Manufacturer documentation
i25 / i29 Instructions for use, installation and maintenanceTable 9: A01 — No burner ignition; causes include no gas, electrode fault, faulty gas valve, low ignition power and excessive condensate.
Last verified
2026-09-12
Frequently asked questions
What does Ferroli A01 mean?
No burner ignition.
Can I reset a Ferroli A01 fault?
Ferroli states that A faults cause permanent shutdown and may be restored with the RESET button only after the fault is eliminated.