Verified boiler fault code
Baxi E133 Fault Code (Baxi and legacy Baxi/Main/Potterton ranges listed on common-code page)
Gas supply fault.
Safety disclaimer
Fault code summary
- Manufacturer
- Baxi
- Fault code
- E133
- Fault type
- Gas supply, Ignition, Flame failure
- Severity
- high
- Reset
- Not specified
- Applicable models
- Baxi Platinum Compact Combi, Baxi Duo-tec Compact Combi, Baxi Megaflo Compact System, Main Eco Compact Combi & System, Baxi 600 Combi & System, Baxi 800 Combi & System, Baxi Duo-tec Combi, Baxi Assure Combi & System, Baxi Platinum + Combi, Potterton Assure Combi & System, Baxi Platinum + Combi, Baxi Megaflo System, Baxi EcoBlue Combi & System
Quick answer
Gas supply fault.
What does this fault code mean?
Gas supply fault.
Common causes
- Gas supply fault; Baxi lists power supply, sensing electrode, spark electrode and cable among checks for this code.
Symptoms
- The boiler may fail to ignite or lock out.
What can the homeowner safely check?
- Check whether other gas appliances work and whether the gas supply is on; do not work on electrodes or cables.
Boiler reset information
Reset information was not provided in the verified manufacturer source. Do not repeatedly reset an unresolved fault.
When should I call an engineer?
Contact a suitably qualified heating engineer when the fault persists, the boiler locks out, or the manufacturer instructions do not resolve it. For gas appliance work in the UK, use a Gas Safe registered engineer.
Engineer diagnosis
- Investigate gas supply, power, ignition electrodes and associated cable.
Applicable boiler models
- Baxi Platinum Compact Combi
- Baxi Duo-tec Compact Combi
- Baxi Megaflo Compact System
- Main Eco Compact Combi & System
- Baxi 600 Combi & System
- Baxi 800 Combi & System
- Baxi Duo-tec Combi
- Baxi Assure Combi & System
- Baxi Platinum + Combi
- Potterton Assure Combi & System
- Baxi Platinum + Combi
- Baxi Megaflo System
- Baxi EcoBlue Combi & System
Related fault codes
- E09 — Baxi and legacy Baxi/Main/Potterton ranges listed on common-code page
Gas-valve connection fault.
Read fault code - E110 — Baxi and legacy Baxi/Main/Potterton ranges listed on common-code page
Boiler maximum temperature exceeded for gradient, or safety thermostat sensor tripped.
Read fault code - E118 — Baxi and legacy Baxi/Main/Potterton ranges listed on common-code page
Water pressure low (below 0.5 bar).
Read fault code - E12 — Baxi and legacy Baxi/Main/Potterton ranges listed on common-code page
Differential water-flow switch fault (still open).
Read fault code - E125 — Baxi and legacy Baxi/Main/Potterton ranges listed on common-code page
Water circulation fault.
Read fault code - E128 — Baxi and legacy Baxi/Main/Potterton ranges listed on common-code page
Safety error for frequent loss of flame.
Read fault code - E130 — Baxi and legacy Baxi/Main/Potterton ranges listed on common-code page
Flue thermostat sensor tripped (lockout).
Read fault code - E160 — Baxi and legacy Baxi/Main/Potterton ranges listed on common-code page
Fan fault.
Read fault code
Manufacturer documentation
Baxi Error CodesE133 | Gas supply fault. Check the power supply, sensing electrode, spark electrode and cable.
Last verified
2026-09-12
Frequently asked questions
What does Baxi E133 mean?
Gas supply fault.