Verified boiler fault code
Warmflow E15 Fault Code (Agentis Boilers (B-Series, I-Series and E-Series))
CH return NTC error.
Safety disclaimer
Fault code summary
- Manufacturer
- Warmflow
- Fault code
- E15
- Fault type
- Temperature sensor, Central heating
- Severity
- medium
- Reset
- The manual states that E15 is stored in error history for diagnosis and is not displayed on the LCD; no user reset is confirmed.
- Applicable models
- B21, B26, B33, I21, I26, I33, I44, I21PRO, I26PRO, I33PRO, I44PRO, I21P/PRO, I26P/PRO, I33P/PRO, I44P, I21S/PRO, I26S/PRO, I33S/PRO, I21C/PRO, I26C/PRO, I33C/PRO, E21, E26, E33, E44, E21PRO, E26PRO, E33PRO, E44PRO, E21P/PRO, E26P/PRO, E33P/PRO, E44P, E21S/PRO, E26S/PRO, E33S/PRO, E21C/PRO, E26C/PRO, E33C/PRO
Quick answer
CH return NTC error.
What does this fault code mean?
CH return NTC error.
Common causes
- CH-return NTC temperature sensor short circuit or disconnection
Symptoms
- E15 stored in the error history; it is not displayed on the LCD
What can the homeowner safely check?
- Record any stored code and arrange qualified service; do not access the sensor.
Boiler reset information
The manual states that E15 is stored in error history for diagnosis and is not displayed on the LCD; no user reset is confirmed.
When should I call an engineer?
Contact a suitably qualified heating engineer when the fault persists, the boiler locks out, or the manufacturer instructions do not resolve it. For gas appliance work in the UK, use a Gas Safe registered engineer.
Engineer diagnosis
- A qualified engineer should inspect the CH-return NTC sensor, wiring and control board.
Applicable boiler models
Related fault codes
- E01 — Agentis Boilers (B-Series, I-Series and E-Series)
Burner lockout.
Read fault code - E02 — Agentis Boilers (B-Series, I-Series and E-Series)
High limit.
Read fault code - E05 — Agentis Boilers (B-Series, I-Series and E-Series)
Boiler NTC error.
Read fault code - E06 — Agentis Boilers (B-Series, I-Series and E-Series)
DHW flow NTC error.
Read fault code - E11 — Agentis Boilers (B-Series, I-Series and E-Series)
Tank limit.
Read fault code - E12 — Agentis Boilers (B-Series, I-Series and E-Series)
Tank-control NTC error.
Read fault code - E22 — Agentis Boilers (B-Series, I-Series and E-Series)
Flash data corrupted.
Read fault code - E31 — Agentis Boilers (B-Series, I-Series and E-Series)
Remote-control communication error.
Read fault code
Manufacturer documentation
Warmflow Agentis Boiler Manual 6572 GError codes displayed on the LCD: | E15* | CH Return NTC Error | CH Return NTC Temperature Sensor short circuit or disconnected | Consult Service Engineer | *Error Codes E11, E15 are not displayed on the LCD, and are only stored in the Error History for diagnosis.
Last verified
2026-09-12
Frequently asked questions
What does Warmflow E15 mean?
CH return NTC error.
Can I reset a Warmflow E15 fault?
The manual states that E15 is stored in error history for diagnosis and is not displayed on the LCD; no user reset is confirmed.