Intergas 8 Fault Code (Combi Compact HRE)
Incorrect fan speed.
Safety disclaimer
Fault code summary
- Manufacturer
- Intergas
- Fault code
- 8
- Fault type
- Fan, Electrical
- Severity
- Not specified
- Reset
- After the fault is rectified, press the reset key on the operating panel.
- Applicable models
- HRE 24/18, HRE 28/24, HRE 36/30, HRE 36/40
Quick answer
Incorrect fan speed.
What does this fault code mean?
Incorrect fan speed.
Common causes
- Fan catching on casing.
- Wiring issue.
- Poor wire contact.
- Fan fault.
Symptoms
- The fault LED flashes and the main display shows 8.
What can the homeowner safely check?
- Record the code and do not remove the casing.
Boiler reset information
After the fault is rectified, press the reset key on the operating panel.
When should I call an engineer?
Contact a suitably qualified heating engineer when the fault persists, the boiler locks out, or the manufacturer instructions do not resolve it. For gas appliance work in the UK, use a Gas Safe registered engineer.
Engineer diagnosis
- Investigate fan movement, wiring, tachometer feedback and the fan.
Applicable boiler models
Related fault codes
- 0 — Combi Compact HRE
Sensor fault after self-check.
Read fault code - 0.0 — Combi Compact HRE
Low pressure.
Read fault code - 1 — Combi Compact HRE
Temperature too high.
Read fault code - 10 — Combi Compact HRE
Sensor fault S1.
Read fault code - 11 — Combi Compact HRE
Sensor fault S1.
Read fault code - 12 — Combi Compact HRE
Sensor fault S1.
Read fault code - 13 — Combi Compact HRE
Sensor fault S1.
Read fault code - 14 — Combi Compact HRE
Sensor fault S1.
Read fault code
Manufacturer documentation
Combi Compact HRE Installation, service and user instructionsSection 11.1: Main display 8 — Incorrect fan speed; table lists fan, casing and wiring causes.
Last verified
2026-09-12
Frequently asked questions
What does Intergas 8 mean?
Incorrect fan speed.
Can I reset a Intergas 8 fault?
After the fault is rectified, press the reset key on the operating panel.